# LED Flood and Area Lighting for Lots and Yards | Maes

> LED flood and area lighting for parking lots, façades and perimeters. Type II to V distributions and narrow to wide beams across five documented families.

Canonical page: https://maeslighting.com/products/flood-area-lighting

Product category · Exterior

# LED flood and area lighting for lots, yards and façades.

Exterior fixtures for parking, roadway, campus and perimeter work on 15 to 50 foot poles. Area optics spread light evenly across a surface; flood optics put directional output where it is aimed.

Complete category lineup

## The complete flood and area lineup.

Browse every family in the range. The EDGE family is also rated for high temperature service — its card opens the full specification page.

AST-FL-13

AST-FL-13 Large LED Flood and Area Lights, IP65, 153 lm per W

Page: https://maeslighting.com/products/flood-area-lighting/ast-fl-13

EDGE Series (60-80C)

EDGE Series High Temperature LED Flood and High Bay, up to 100°C

Page: https://maeslighting.com/products/high-temperature-lighting/edge-60-80c

LS-ESBV Shoebox

LS-ESBV Shoebox LED Area Lights for Parking Lots, Type III and V

Page: https://maeslighting.com/products/flood-area-lighting/ls-esbv

LS-FL Tunable

LS-FL Tunable LED Flood Lights, Power and CCT Selectable, IP65

Page: https://maeslighting.com/products/flood-area-lighting/ls-fl-tunable

RT Series

RT Series High Lumen LED Flood Lights, IP66, 10° to 90° Beams

Page: https://maeslighting.com/products/flood-area-lighting/rt-series

At a glance

## Compare flood and area families by distribution and output.

Distribution type decides the family for area work; beam angle decides it for flood work. Start there, then size the output to the pole plan.

**At-a-Glance LED Flood and Area Lights for Parking Lots, Model Comparison**

| Family | Wattage options | Lumen range | Efficacy | Voltage | CCT | Optics or Beam |
| --- | --- | --- | --- | --- | --- | --- |
| LS-ESBV Shoebox Area | 100, 150, 200, 240, 300 W | 13,000 to 39,000 lm | 130 lm/W | 120 to 277 V, 277 to 480 V options | 3000, 4000, 5000 K | Type III or V |
| LS-FL Tunable Flood | 15 to 150 W, power and CCT switchable | 2,025 to 20,250 lm | 135 lm/W | 120 to 277 V, 120 to 347 V | 3000, 4000, 5000 K | 120° beam |
| RT Series High-Lumen Flood | 100, 150, 200, 240, 300, 400, 500, 720, 1000, 1500 W | est. 16,000 to 240,000 lm from 160 lm/W × power | 160 lm/W | 90 to 305 V | 2800 to 7500 K | 10°, 25°, 40°, 60°, 90° |
| AST-FL-13 Large Flood | 240, 300 W | 36,720 to 45,900 lm | 153 lm/W | 120 to 277 V | 5700 K | 130×100° beam |
| EDGE Series High Temperature LED Flood and High Bay, up to 100 °C | 50, 100, 150, 200, 300, 450 W | 7,000 to 63,000 lm | 130 to 160 lm/W | 100 to 277 V, 200 to 480 V | 2500 to 5500 K options | 15 lens options, 20° to 150°, 30×100°, 60×100°, 130×70°, 70×135°, 75×145°, 60×150°, 73×133° |

One lumen range in the comparison is a calculated estimate from efficacy rather than a per-model measurement, and it is labelled as an estimate accordingly.

### Related categories

If the limiting condition is different, one of these is usually the better starting point.

- [High TemperatureWhere radiant or ambient heat is a factor.](https://maeslighting.com/products/high-temperature-lighting)
- [High BayInterior equivalents for tall covered space.](https://maeslighting.com/products/high-bay-lighting)
- [EmergencyEgress and backup duty on the same sites.](https://maeslighting.com/products/emergency-lighting)

Specification path

## Distribution first, then pole height, then wattage.

Even coverage on a lot comes from the right distribution type at the right spacing, not from more wattage. Confirm pole height and spacing, the distribution or beam required, voltage, and any dark-sky, glare or trespass constraint the site is subject to before comparing output.

> Area lights and flood lights solve different problems. One spreads light across a surface; the other aims it at a target.

## Include in your quote request

Application

Lot, façade, yard or perimeter

Pole

Height and spacing

Optic

Type II–V or beam angle

Voltage

120–277 V or 277–480 V

Constraints

Glare, trespass, dark sky

Common questions

## Frequently asked questions

These answers clarify the selection process without replacing project-specific documentation.

**What is the difference between an area light and a flood light?**

Area lights use Type II to Type V distributions to spread light evenly across a surface such as a parking lot. Flood lights use narrower beams to aim output at a façade, sign or work zone.

**Which distribution suits a parking lot?**

Type III and Type V distributions are available for the shoebox area family. The right choice depends on pole placement relative to the lot edge, so confirm the layout before selecting.

**Are any of these fixtures rated for high ambient temperatures?**

The EDGE family carries elevated-ambient ratings and also serves high temperature applications — its family page has the full specification table.

---

Maes Lighting — nationwide supplier of certified explosion proof, industrial, high-temperature,
food-processing, vapor-tight, high-bay, flood, area, and emergency LED lighting.
Headquarters: Broken Arrow, Oklahoma. Sales: (866) 860-6399 · tjacobs@maeslighting.com
Website: https://maeslighting.com
