# LS-ESBV Shoebox LED Area Lights | Maes Lighting

> LS-ESBV shoebox area light specifications: 100 W to 300 W, 13,000 to 39,000 lumens, Type III and Type V distributions and three colour temperatures.

Canonical page: https://maeslighting.com/products/flood-area-lighting/ls-esbv

Product family · Flood & Area

# LS-ESBV shoebox LED area lights.

A pole-mounted shoebox area light for parking and campus work, documented from 100 W to 300 W in Type III and Type V distributions.

LS-ESBV configurations

## Every documented LS-ESBV configuration.

One family, every configuration: the fixture is shown at full size, with each available configuration listed below and specified line by line in the ordering table.

- LS-ESBV7E100WAT3A1Wattage: 100 W13,000 lm
- LS-ESBV7E150WAT3A1Wattage: 150 W19,500 lm
- LS-ESBV7E200WAT3A1Wattage: 200 W26,000 lm
- LS-ESBV7E240WAT3A1Wattage: 240 W31,200 lm
- LS-ESBV7E300WAT3A1Wattage: 300 W39,000 lm

Ordering data

## Every documented LS-ESBV configuration.

All 5 configurations of the family are specified on this page, so you can compare wattages, outputs and options side by side.

**LS-ESBV Shoebox LED Area Lights for Parking Lots, Type III and V**

| Model | Wattage | Typical Lumens | Voltage | Distribution | CCT Options | BUG |
| --- | --- | --- | --- | --- | --- | --- |
| LS-ESBV7E100WAT3A1 | 100 W | 13,000 lm | 120 to 277 V AC | Type III or Type V | 3000 K, 4000 K, 5000 K | B3-U0-G3 |
| LS-ESBV7E150WAT3A1 | 150 W | 19,500 lm | 120 to 277 V AC | Type III or Type V | 3000 K, 4000 K, 5000 K | B3-U0-G3 |
| LS-ESBV7E200WAT3A1 | 200 W | 26,000 lm | 120 to 277 V AC | Type III or Type V | 3000 K, 4000 K, 5000 K | B4-U0-G3 |
| LS-ESBV7E240WAT3A1 | 240 W | 31,200 lm | 120 to 277 V AC | Type III or Type V | 3000 K, 4000 K, 5000 K | B4-U0-G4 |
| LS-ESBV7E300WAT3A1 | 300 W | 39,000 lm | 120 to 277 V AC | Type III or Type V | 3000 K, 4000 K, 5000 K | B4-U0-G4 |

Confirm the exact configuration against the current manufacturer specification sheet before approval or purchase.

Engineering reference

## Selecting within the LS-ESBV family.

Pole position relative to the lot decides the distribution: Type III for perimeter poles, Type V for poles inside the area. Then pole height and spacing set the wattage. The documented BUG rating matters where the site is subject to trespass or dark-sky constraints.

Area lighting is a distribution problem before it is an output problem. Type III throws forward from a pole at the edge of a lot; Type V spreads symmetrically from a pole within it. Choosing the wrong one wastes light off-site and leaves gaps on the surface, which more wattage does not fix.

Controlled document

## LS-ESBV specification sheet

The manufacturer's specification sheet remains the controlling project document.

[Download specification sheet](https://storage.googleapis.com/msgsndr/ZuNLM6pdiP00w1G1is8O/media/68b9ffd06510b977e8604b8b.pdf)

Common questions

## Useful answers before the next step.

These answers clarify the selection process without replacing project-specific documentation.

**Which distribution suits a parking lot?**

It depends on pole placement. Type III projects forward and suits poles at the lot edge; Type V distributes symmetrically and suits poles within the lot. Confirm the layout before selecting.

**What is the BUG rating for?**

Backlight, uplight and glare. This family carries a B3-U0-G3 rating, which matters where the site is subject to light trespass or dark-sky requirements — U0 means no uplight at all.

---

Maes Lighting — nationwide supplier of certified explosion proof, industrial, high-temperature,
food-processing, vapor-tight, high-bay, flood, area, and emergency LED lighting.
Headquarters: Broken Arrow, Oklahoma. Sales: (866) 860-6399 · tjacobs@maeslighting.com
Website: https://maeslighting.com