Product family · Emergency

HPRL high-performance remote fixtures.

Remote emergency heads for areas where the battery cannot be located, documented in one and two head configurations from 6 W to 15 W.

HPRL HPRL High-Performance Remote Fixtures
Remote heads · 6 W to 15 W · NEMA 4X

HPRL configurations

Every documented HPRL configuration.

One family, every configuration: the fixture is shown at full size, with each available configuration listed below and specified line by line in the ordering table.

HPRL HPRL High-Performance Remote Fixtures
  1. HPRL L6Heads: 16 W
  2. HPRL L10Heads: 110 W
  3. HPRL L15Heads: 115 W
  4. HPRLD L6Heads: 26 W each
  5. HPRLD L10Heads: 210 W each
  6. HPRLD L15Heads: 215 W each

Ordering data

Every documented HPRL configuration.

All 6 configurations of the family are specified on this page, so you can compare wattages, outputs and options side by side.

HPRL High-Performance Remote Fixtures, NEMA 4X
ModelHeadsLED headOutputInputOperating tempKey ratings
HPRL L616 W565 lm12 to 24 V DC-40 to 131 °FNEMA 4X, UL 924
HPRL L10110 W1000 lm12 to 24 V DC-40 to 131 °FNEMA 4X, UL 924
HPRL L15115 W1300 lm12 to 24 V DC-40 to 131 °FNEMA 4X, UL 924
HPRLD L626 W each565 lm each12 to 24 V DC-40 to 131 °FNEMA 4X, UL 924
HPRLD L10210 W each1000 lm each12 to 24 V DC-40 to 131 °FNEMA 4X, UL 924
HPRLD L15215 W each1300 lm each12 to 24 V DC-40 to 131 °FNEMA 4X, UL 924

Confirm the exact configuration against the current manufacturer specification sheet before approval or purchase.

Engineering reference

Selecting within the HPRL family.

Confirm the battery unit first, since these heads draw from it and its capacity determines how many can be supported. Then head count and output per position. The documented −40 to 131 °F range is the widest in the emergency range, which is often why this family is chosen.

HPRL solves a placement problem rather than a lighting one. Where egress illumination is required but a battery unit cannot be mounted — restricted ceilings, washdown zones, classified boundaries — remote heads run from a separate unit over low-voltage wiring.

Common questions

Useful answers before the next step.

These answers clarify the selection process without replacing project-specific documentation.

What powers these fixtures?

A separate battery unit over 12 to 24 V DC wiring. The unit's capacity at the required duration determines how many remote heads it can support, so specify the unit and the heads together.

What operating range is documented?

−40 to 131 °F, the widest in the emergency range, with NEMA 4X construction and UL 924 listing.

Build the specification

Bring us the conditions. We’ll help narrow the fixture.

Share the classification, temperature, ingress, mounting and timeline for a focused product conversation.