Class I Div 1 / Div 2
EXI
Explosion proof linear LED
View product pageProduct category · Hazardous locations
UL844 fixture families for Class I Division 1 and Division 2 environments, selected around the site’s official classification, gas or dust groups, temperature code and mounting conditions.
Complete category lineup
Thirteen explosion proof families at a glance. Open any family page for the full specification table, certifications and downloadable documentation.

Class I Div 1 / Div 2
EXI
Explosion proof linear LED
View product page
Class I Div 2
IR1
Non-metallic hazardous linear LED
View product page
Class I Div 2
IR3
Marine hazardous-location linear LED
View product page
Class I Div 1
IR4
Explosion proof linear LED
View product page
Class I Div 2
IR7
High-output hazardous linear LED
View product page
Class II Div 1
EXH
Hazardous-location linear LED
View product page
Class I Div 2
EXA
Hazardous-location flood light
View product page
Class I Div 1
EX-C
Explosion proof LED flood light
View product page
Class I Div 1
EXD
Explosion proof flood and high bay
View product page
Class I Div 1
EX-MV01
Portable explosion proof work light
View product page
UL924
EX-ES03
Explosion proof exit and emergency light
View product page
Class I Div 2
FYS / FYD
Explosion proof LED light
View product page
Class I Div 2
FFS / FFD
Explosion proof LED flood light
View product pageAt a glance
Wattage and output figures come straight from each family’s specification table. Where the manufacturer publishes no figure, the cell says “Not published” rather than an estimate.
| Family | Form factor | Classification | Wattage | Typical lumens |
|---|---|---|---|---|
| EXI | Linear · 2 ft and 4 ft | Class I Div 1 / Div 2 | 20–120 W | 2,800–16,800 lm |
| IR1 | Linear · non-metallic | Class I Div 2 | 40 W | 4,400 lm |
| IR3 | Linear · marine | Class I Div 2 | 92 W | 16,000 lm |
| IR4 | Linear | Class I Div 1 | 70 W | 13,000 lm |
| IR7 | Linear · high output | Class I Div 2 | 80–240 W | 8,800–26,400 lm |
| EXH | Linear | Class II Div 1 | 10–60 W | 1,400–8,400 lm |
| EXA | Flood | Class I Div 2 | 20–200 W | Not published |
| EX-C | Flood | Class I Div 1 | 20–300 W | 14,000–42,000 lm (some rows N/A) |
| EXD | Flood and high bay | Class I Div 1 | 60–300 W | Not published |
| EX-MV01 | Portable work light | Class I Div 1 | 5–19.5 W rated | 1,600 lm on high |
| EX-ES03 | Exit and emergency | UL924 | 2 × 5 W heads · 3–5 W legend | Not published |
| FYS / FYD | Round high bay | Class I Div 2 | 20–200 W | 3,000–30,000 lm |
| FFS / FFD | Flood | Class I Div 2 | 20–200 W | 3,000–30,000 lm |
Classifications shown are family-level. Individual configurations within a family can carry different certifications — confirm the exact catalog number against its specification sheet.
Fixture families
Products are organized by work area and form factor, so you compare only the families that fit your application.
Specification path
Confirm the site’s official area classification and applicable gas, vapor, dust or fiber groups. Then verify temperature code, ambient range, ingress, corrosion exposure, optics, mounting and controls against the selected fixture documentation.
A product family may offer several certifications and ratings. Always match the exact configuration to the project requirements.
Common questions
These answers clarify the selection process without replacing project-specific documentation.
Confirm the official class, division, gas or dust group, temperature code, ambient range, ingress, corrosion exposure, mounting and control requirements.
Not necessarily. Certifications and ratings can vary by configuration, so the exact catalog selection must be checked against the project documentation.
Build the specification