Product family · explosion-proof-lighting

EX-MV01 portable explosion proof work light.

A battery-powered work light for classified areas, documented at 1,600 lumens on high with runtime up to 10 hours.

EX-MV01 EX-MV01
Portable · 1,600 lm · up to 10 h

EX-MV01 selection guide

EX-MV01 models and options.

Compare the documented models and options below. A family name or model reference may need additional selections before it becomes a complete product order code.

EX-MV01 EX-MV01
Family reference image; appearance may vary by model and selected options.
  1. EX-MV01Modes: High, Low, FlashingOutput and runtime: 1600 lm high, ≥500 lm work, up to 10 h

For a quote or submittal, include the model reference and required options from the specification table. Our team will confirm the complete order code and current documentation.

Specification comparison

EX-MV01 models and specifications.

Compare 1 documented specification row. A row may describe a model, a model group or several selectable options; it does not necessarily represent one complete order code.

On smaller screens, scroll the table horizontally to see every specification.

ModelModesOutput and runtimeBeam and CCTPower and batterySize and weightRatings and certifications
EX-MV01High, Low, Flashing1600 lm high, ≥500 lm work, up to 10 h125°, 4500 to 5000 K10.8 V 9 Ah Ni-MH, rated 5 to 19.5 W386×210×237 mm, deploy height 567 to 825 mm, 7 kgIP66, -20 to +40°C, UL844 C1D1 Groups A B C D T4, Class I Zone 0 AEx ia IIC T4 Ga, Ex ia IIC T4 Ga

Confirm the exact configuration against the current manufacturer specification sheet before approval or purchase.

Engineering reference

Choosing the right EX-MV01 configuration.

Confirm the classification the light will enter, since Zone 0 approval is what distinguishes it. Then match runtime to the shift or task: three output modes are available, and runtime varies with the mode selected. Weight and deploy height matter for portability planning.

EX-MV01 is the only portable fixture in the catalogue, and the only one whose specification is a battery rather than a driver. It is documented for Class I Division 1 and Zone 0 — the most demanding classification here — which is what makes it appropriate for entry, inspection and maintenance work inside a classified boundary.

Common questions

Frequently asked questions

These answers clarify the selection process without replacing project-specific documentation.

What runtime is documented?

Up to 10 hours, at 1,600 lumens on high and 500 lumens or more in work mode. Runtime varies with the mode selected, so size against the mode the task requires.

What approvals does this carry?

UL844 Class I Division 1 Groups A to D T4, and Class I Zone 0 AEx ia IIC T4 Ga with Ex ia IIC T4 Ga. Zone 0 is the most demanding classification in this catalogue.

What are the physical dimensions?

386 × 210 × 237 mm at 7 kg, with a deploy height of 567 to 825 mm. Worth checking against access routes and confined-space entry before specifying.

Build the specification

Send us your site conditions. We’ll recommend the right fixture.

Share the classification, temperature, ingress, mounting and timeline for a focused product conversation.